Standard TFC Membrane - 90 gpd

Standard TFC Membrane - 90 gpd

Brief Description: Replacement TFC membrane fits all standard Reverse Osmosis (RO) units including SpectraPure, Kent, Ultralife, Sandpoint, Dow, Coralife, Culligan and many others.
  • Product No. ROSP-TFCK-90 - Ships in 2 to 7 days
Price: $56.31






  • SpectraPure standard membranes are un-tested versions of the SpectraSelect membranes. They are not "rejects"; they just haven't gone through rigorous testing procedures. They are treated with a proprietary process to enhance the rejection and production rates and are QC batch tested to insure rated performance within manufacturer tolerances.

  • The membranes produce the rated GPD ± 20% at 60 psi.
    Minimum Rejection = 96%; Stabilized Salt Rejection = 98%. (Permeate flow and salt rejection based on the following test conditions: 250 ppm TDS, 77°F (25°C), 15% recovery and the specified applied pressure).

  • These membranes are standard equipment in SpectraPure's MPRO, MPDI, CSP, CSPDI, MaxCap RO/DI and all Drinking Water Systems.

  • All membranes up to 90 GPD will fit in SpectraPure's standard membrane housing. The standard membrane is also available as a replacement option for most competitors' reverse osmosis systems.

  • Membranes must be matched with flow restrictors. Always change the flow restrictor when changing membrane size on a system.

  • Tip: If you need to replace the membrane, take the opportunity to increase your Reverse Osmosis (RO) Systems production rate by purchasing a membrane with a higher flow rate along with a matching flow restrictor. E-mail or call for further information.

  • Image shown is the SpectraPure Standard 60 gallon per day membrane.


Cole's Notes: Membrane Replacement.

Only purchase a RO replacement membrane when it's needed unless you think you'll need to replace it shortly and would like to have one on hand. Wet membranes can be stored in a refrigerator for up to 1 year. (Keep it in its sealed, original packaging). If the membrane dries out, it will not produce water.

Under normal use, a membrane can be expected to last approximately 2 years but they should be tested every 6 months or so. A TDS meter can give a good indication when it's time to change the membrane. Measure the TDS of both the feed water and product water. If the rejection rate is 95% or better, the membrane is okay. If not, it's time to replace it.

The higher the rejection rate, the better. A 2% difference in the rejection rate can save you big $$$ in DI cartridges. You'll only need to replace your DI cartridge half as often using a membrane with a rejection rate of 98% versus one with a 96% rejection rate. That's a good reason to buy a membrane with a higher rejection rate like SpectraPure membranes. All of their membranes are subjected to a proprietary process which increases their rejection ratio over the membranes purchased by other vendors, even from the same supplier.

When it is time to replace your membrane, its a good idea to consider boosting the output of your RO unit. For example, the capacity of a 25, 50 or 60 gpd RO or RO/DI can be increased to a 90 gpd just by purchasing a 90 gpd membrane and matching flow restrictor.


There are no reviews for this item at present. If you use this product please let us know what you think of it.

Average rating based on 0 review(s)  

Write Review

Do you want to add this item to your wishlist?